• Benefits
  • Gallery
  • Testimonials
  • News
  • Tax Credits
Home Company
Profile
Product
Spotlight
Breast
Health
Urology Neonatal Labor &
Delivery
OB/GYN Critical
Care
Radiology Respiratory
Care
Surgery Contact
Sales

Medical Respiratory Care Equipment



We provide leading health care equipment at affordable prices. We have taken great care in picking quality brands to provide to our clients, and would like to answer any questions you may have. Contact us today through our website or at: 800-649-4028.


Our Products:
The Cannulaide®
Sticky Whiskers®
Mini Whiskers®
Tilson Trach Guard
Trach Guard Tether
Oxygen Analyzers & Monitors
Oxygen Sensors-Medical Anesthesia
Oxygen Sensors- Medical Respiratory
Custom Trays
Endotracheal Tube Holder
Videos:
Intro
Across the Face Application
Over the Head Application
Ex-Vivo Lung Demo
Sticky Whiskers

Products:

Intro


The Cannulaide®

Nasal CPAP seal and attachment made easy.
Infant Nasal CPAP is on the rise. As many as 10% of all babies born in the US can benefit from some degree of breathing support. For some infants treatment is needed only for a few hours while for others it may be needed for several months. CPAP has been widely used with these infants to reduce their work of breathing. Nasal CPAP is growing in popularity because it avoids intubation or tracheotomization, decreases the risk of nosocomial pneumonia; decreases sedation requirements; and improves the ability to tolerate enteral feeds. The Cannulaide, as an adjunct to this therapy, can improve the quality of the CPAP seal and may help reduce irritation to your patients.

Just as each brand of prongs is designed to fit the range of preemie babies, the Cannulaide, offered in five sizes, will work with the type you use, and with both across-the-face and over-the-head styles of CPAP set up.



CANNULAIDE ORDERING INFORMATION


SIZE PART # FOR BABIES BOX QUANTITY
0 CA100 < 700g Box of 25
1 CA101 < 1250g Box of 25
2 CA102 < 2Kg Box of 25
3 CA103 < 3Kg Box of 25
4 CA104 > 3Kg Box of 25


back to top


Across the Face Application
Over the Head Application
   
Lung
 


Mini Whiskers®

Secure nasal cannulas and OG/NG tubes with our NEW "Mini Whiskers™"

So Little...So Secure...

The Mini Whiskers™ helps to keep the cannula in place directly under the infant's nose with soft, low-profile Velcro®. The Mini Whiskers™ gently attach to the skin with hydrocolloid adhesive and ensures easy changes to the placement of the cannula.
  • For babies less than 2000g
  • Gentle on the skin
  • Cost effective
  • Easy to use
  • Minimal intrusion
Our Mini Whiskers™ secure the cannula and OG/NG tubes so they stay on the baby but remain repositionable. The Mini Whiskers™ give you safe and simple securement!

After cleaning the skin, apply the Mini Whiskers™ and then simply wrap the soft Velcro® loop strips around the cannula "like a candy cane". Then, place your cannula directly under the nose. With the Mini Whiskers™ there is no tension on the septum, ears, or taping the tubing to the face causing creases.

The Mini Whiskers™ can also be used to secure OG/NG tubes. The soft Velcro® tabs can be secured to the OG tube in a "flag" configuration. When it’s time to change sides, the flag can be moved from one side to the other with good confidence of tube depth being consistent.



back to top


Sticky Whiskers®

Secure nasal cannulas gently with "Sticky Whiskers®"
Securing tubes to infants has proven to be a challenge. In the past, cannulas have often been held in place with tapes that are too aggressive causing skin issues or requiring significant handling of the infant in order to relocate the device. However, if the adhesive is too light, the tubes become dislodged.

Our Sticky Whiskers Velcro® interface allows a cannula to be secure yet still repositionable.

After applying the Sticky Whiskers™ to the upper lip, simply wrap the soft Velcro® loop strips around the cannula "like a candy cane" and place your cannula in place directly under the nose. No tension on the septum, ears or taping the tubing to the face causing face creases.

The Sticky Whiskers™ can also be used to secure OG tubes if necessary. The soft Velcro® tabs can be secured to the OG tube in a "flag" configuration. When it’s time to change sides, the flag can be moved from one side to the other with good confidence of tube depth being consistent.



back to top


Sticky Whiskers


Tilson Trach Guard

Protecting the exposed trach from accidental external occlusion. The Tilson Trach Guard is a tracheostomy tube protector. It helps prevent blocking of the tube opening by chubby chins, bedding, gauze dressings, clothing, and so on. Unlike artificial noses, tee pieces, etc. the Tilson Trach Guard has a low profile and doesn't get clogged by even copious secretions or coughed-up mucous plugs. The Trach Guard is reported to be effective at stopping or deflecting these bits so they are not projected forward.

Item #  
TP100 ( box of 25 )


back to top


Trach Guard Tether

Our special Trach Tether keeps Tilson Trach Guard safe and secure. A number of our customers have told us that they wanted something to keep the Tilson Trach Guard from falling to the floor if the patient dislodges the guard or the care giver drops it while cleaning the patient's trach. We came up with the inexpensive solution you see to the right (Tilson Trach Guard not included)

back to top


Oxygen Analyzers & Monitors

AII-2000 M Oxygen Monitor
Auto diagnostics, menu driven state-of-the-art electronics, audible and visual HI-LO alarms, LO alarm 15-99% oxygen, HI alarm 16-100% oxygen, large backlit LCD for easy viewing, integral tripod stand and dove tail bracket. Proprietary advanced galvanic sensor capable of oxygen analysis from 0-100% and 60 months expected life in air. General-purpose monitor operates 1,500 hours on 2 AA Alkaline batteries. Optional carrying case.

Ranges - Standard: 0-100%
Application - Continuous use or spot check respiratory therapy ventilators, neo-natal incubators, anesthesia.


AII-2000 HC Oxygen Analyzer
Auto diagnostics, menu driven state-of-the-art electronics, internal oxygen sensor, large backlit LCD for easy viewing, integral tripod stand and dove tail bracket. Proprietary advanced galvanic sensor capable of oxygen analysis from 0-100% and 60 months expected life in air. General purpose analyzer operates 1,500 hours on 2 AA Alkaline batteries. Optional carrying case.

Ranges - Standard: 0-100%
Application - Spot checking tanks, concentrators and oxygen systems


AII-2000 A Oxygen Analyzer

Auto diagnostics, menu driven state-of-the-art electronics, large backlit LCD for easy viewing, integral tripod stand and dove tail bracket. Proprietary advanced galvanic sensor capable of oxygen analysis from 0-100% and 60 months expected life in air. General purpose analyzer operates 1,500 hours on 2 AA Alkaline batteries. Optional carrying case.

Ranges - Standard: 0-100%
Application - Spot checking respiratory therapy ventilators, neo-natal incubators, anesthesia

back to top


Oxygen Sensors-Medical Anesthesia

Item Number OEM Analyzer / Manufacturer Replaces Competitive Sensor Image
PSR-11-915
Range: 0-100% Oxygen
Signal Output: 53-67μA
Response 90%: < 20 sec
Expected Life: 60 months
Warranty: 18 months
Ohmeda 4700 Oxicap 0237-2034-700
Ohmeda 5100 O2 Monitor 0237-2034-700
Ohmeda 5120 O2 Monitor 0237-2034-700
Ohmeda 5140 O2 Monitor 0237-2034-700
Ohmeda 5250 0237-2034-700
Ohmeda 5250 RGM 0237-2034-700
Ohmeda 7200 O2 Monitor 0237-2034-700
Ohmeda 7800 O2 Monitor 0237-2034-700
Ohmeda 7810 O2 Monitor 0237-2034-700
Ohmeda Excel Series 0237-2034-700
Ohmeda Modules Series 0237-2034-700
EnviteC OOM101
International Tech (Gambert) M-01
Maxtec (Ceramatec) MAX-1
MSA (Catalsyt Research) 655263
Ohmeda 0237-2034-700
Pacifitech PT-14
Paragon Services PS-1000
Sensor Tec (BPR Medical) ST-10
Teledyne R15 (C-41131)
Vascular Technology 101272
PSR-11-915-1
Range: 0-100% Oxygen
Signal Output: 53-67μA
Response 90%: < 20 sec
Expected Life: 60 months
Warranty: 18 months
None - See Competitive Sensor Maxtec (Ceramatec) MAX-2 Pacifitech PT-24A
Physio Control 803000-18
Teledyne Class R-31
PSR-11-915-2
Range: 0-100% Oxygen
Signal Output: 23-30 μA
Response 90%: < 20 sec
Expected Life: 60 months
Warranty: 18 months
Drager Cato 6850645
Drager Fabius 6850645
Drager Narcomed 1A 6850645
Drager Narkomed 2 6850645
Drager Narkomed 2B 6850645
Drager Narkomed 3 6850645
Drager Narkomed 4 6850645
Drager Naromed 6000 6850645
Drager EVITA 2 & 4 6850645
Drager Baby Log 6850645
Drager GS 6850645
Drager I8000 6850645
City Technology MOX-6 Drager 6850645
EnviteC OOM104
EnviteC OOM201
Hudson RCI 5557
International Tech (Gambert) M-02 / MO8
Maxtec (Ceramatec) MAX-11
MSA (Catalsyt Research) 655264
Pacifitech PT-14A
Paragon Services PS-2000
Sensor Tec (BPR Medical) ST-14
Teledyne R23 (C-61339)
Vascular Technology 101372
PSR-11-915-3
Range: 0-100% Oxygen
Signal Output: 53-67μA
Response 90%: < 20 sec
Expected Life: 60 months
Warranty: 18 months
None - See Competitive Sensor Maxtec (Ceramatec) MAX-8
Pacifitech PT-28A
Teledyne Class R-32
PSR-11-915-4
Range: 0-100% Oxygen
Signal Output: 53-67μA
Response 90%: < 20 sec
Expected Life: 60 months
Warranty: 18 months
Ohmeda 7900 Smart Vent 6050-004-110
Ohmeda 7100 Smart Vent 6050-004-110
Ohmeda Aestiva 3000 / 5 6050-004-110
EnviteC OOM110
International Tech (Gambert) M-10
Maxtec (Ceramatec) MAX-10
Ohmeda 6050-004-110
Pacifitech PT-20A
Teledyne Class R-30
PSR-11-917-J2
Range: 0-100% Oxygen
Signal Output: 7-13 mV
Response 90%: 13 sec
Expected Life: 60 months
Warranty: 18 months
Datascope Anestar 0600-00-0070 Datascope Anestar 0600-00-0070


back to top


Oxygen Sensors- Medical Respiratory

Item Number OEM Analyzer / Manufacturer Replaces Competitive Sensor Image
PSR-11-55
Range: 0-100% Oxygen
Signal Output: 25-40 mV
Response 90%: 9 sec
Expected Life: 42 months
Warranty: 14 months
Hudson 5577/6477/5590 5500 Hudson RCI - 5500
International Tech (Gambert) - M-13
Maxtec (Ceramatec) - MAX-9
MSA (Catalsyt Research) - 655265
Pacifitech - PT-05
PSR-11-58
Range: 0-100% Oxygen
Signal Output: 70-160 mV
Response 90%: 13 sec
Expected Life: 60 months
Warranty: 18 months
Hudson 5800/5801 5803 Hudson RCI 5803
PSR-11-58HC
Range: 0-100% Oxygen
Signal Output: 70-160 mV
Response 90%: 13 sec
Expected Life: 60 months
Warranty: 18 months
Hudson RCI 5803 5804 Hudson RCI 5804
PSR-11-75-KE1
Range: 0-100% Oxygen
Signal Output: 10-14 mV
Response 90%: 13 sec
Expected Life: 60 months
Warranty: 18 months
Maxtec (Ceramatec) OM2 MAX-25/250 Maxtec (Ceramatec) MAX-25/250
Pacifitech PT-250
PSR-11-75-KE2
Range: 0-100% Oxygen
Signal Output: 10-14 mV
Response 90%: 13 sec
Expected Life: 60 months
Warranty: 18 months
Puritan Bennet G-062010
740 Ventilator (old)
Puritan Bennet G-062010
PSR-11-75-KE4
Range: 0-100% Oxygen
Signal Output: 10-14 mV
Response 90%: 13 sec
Expected Life: 60 months
Warranty: 18 months
Viasys Vela 16101 Viasys Vela 16101
PSR-11-77      
Range: 0-100% Oxygen
Signal Output: 7-13 mV
Response 90%: 6 sec
Expected Life: 60 months
Warranty: 18 months
Newport Wave Ventilator OM100
Newport Wave Ventilator OM105
Sechrist 650 43170
Teledyne 60/191/200 T-7 (A51327)
City Technology MOX-4
EnviteC OOM105
Hudson RCI 5558
International Tech (Gambert) M-07
Maxtec (Ceramatec) MAX-17
PSR-11-917-J      
Range: 0-100% Oxygen
Signal Output: 7-13 mV
Response 90%: 13 sec
Expected Life: 60 months
Warranty: 18 months
Bird Products 6400/8400 66030
Lifecare (Respironics) 37-079
PLV-102
MSA Mini Ox I,II,III,3000 406931
Puritan Bennet 4-020933
7820 Monitor
Respironics (Esprit) 1001454
SLE T-801 monitor
Stephan Christina Ventilat
110760009
Taema (France) Ceasar (newer version)
Taema (France) Eolo R17 (C-43690)
Teledyne AX 300/MX 300
Bird Products Corp. 66030
City Technology MOX-2
EnviteC OOM102-1
Hudson RCI 5567
International Tech (Gambert) M-03
Lifecare (Respironics) 37-079
Maxtec (Ceramatec) MAX-13
Maxtec (Ceramatec) MAX-13-250
MSA (Catalsyt Research) 406931
Pacifitech PT-11
Pacifitech PT-11A
Puritan Bennet 4-020933
PSR-11-917-J1
Range: 0-100% Oxygen
Signal Output: 7-13 mV
Response 90%: 13 sec
Expected Life: 60 months
Warranty: 18 months
Maxtec (Ceramatec) MAX25E/250E
OM25AE
Taema (France) Alys
Taema (France) Clarys
PSR-11-917-J3
Range: 0-100% Oxygen
Signal Output: 7-13 mV
Response 90%: 13 sec
Expected Life: 60 months
Warranty: 18 months
Taema (France) Alys
Taema (France) Clarys
Taema (France) Alys
Taema (France) Clarys
PSR-11-917-M
Range: 0-100% Oxygen
Signal Output: 7-13 mV
Response 90%: 13 sec
Expected Life: 60 months
Warranty: 18 months
Air Shields (Drager) 8362030
C200/C2000
Criticare Systems (Poet ) CAT644
EME Infant Flow CPAP
Infrasonics Adult Star 60116
Puritan Bennet 4-072214-00
760/840 Ventilators
Siemens 300/900 Vent. 6419332
Siemens 300/900 Vent. 9004979
Spacelabs Gas Analyzer 90514
Taema (France) Ceasar (older version)
Viasys Avea 62689
Air Shields (Drager) 8362030
City Technology MOX-9
Criticare Systems (Poet ) CAT644
EME M672P
EnviteC OOM102
EnviteC OOM102-Air
EnviteC OOM103
EnviteC OOM202
Hudson RCI 5566
Infrasonics 60116
International Tech (Gambert) M-04
International Tech (Gambert) M-12
PSR-11-917-M1
Range: 0-100% Oxygen
Signal Output: 7-13 mV
Response 90%: 13 sec
Expected Life: 60 months
Warranty: 18 months
Datascope 0600-00-0002 Datascope 0600-00-0002
EnviteC OOM106
PSR-11-917-MH
Range: 0-100% Oxygen
Signal Output: 7-13 mV
Response 90%: 13 sec
Expected Life: 60 months
Warranty: 18 months
Hamilton Arabella 51254
Hamilton Galileo 51254
Hamilton Ralphael 51254
Hamilton 51254
PSR-11-33
Range: 0-100% Oxygen
Signal Output: 165-235 μA
Response 90%: 30 sec
Expected Life: 24 months
Warranty: 12 months
Bio-med Devices 65004
Hamilton Aladdin 51250
Hamilton Amadeus 51250
Hamilton Veolar 51250
Taema KV050501
Bio-Med Devices 65004
Bio-Tek 74233
EnviteC OOM107
Fraser Lake 66-0453
Hamilton 51250
Hewlett Packard 15201-A
PSR-11-33-1
Range: 0-100% Oxygen
Signal Output: 165-235 μA
Response 90%: 30 sec
Expected Life: 24 months
Warranty: 12 months
  Maxtec (Ceramatec) MAX-18
MSA (Catalsyt Research) 485905
Sensor Tec (BPR Medical) ST-02
Teledyne C1R (B-39022)
PSR-11-33-2
Range: 0-100% Oxygen
Signal Output: 165-235 μA
Response 90%: 30 sec
Expected Life: 24 months
Warranty: 12 months
Hudson 5525 5565
Hudson 5828 5565
Hudson 5550 5565
Hudson 5552 5565
EnviteC OOM107-2
Hudson RCI 5565
International Tech (Gambert) M-06
Maxtec (Ceramatec) MAX-15
MSA (Catalsyt Research) 655262
Pacifitech PT-02
Pacifitech PT-65
Teledyne C2R (B-39023)


back to top


CUSTOM TRAYS
Design your own today!

  • Cost Effective - Custom doesn’t mean costly!
  • Provide excellent care with quality products and instruments.
  • Save time and money by customizing your tray to fit your facility’s needs.
  • Storage an issue? We offer compact trays without the excess bulk.
  • Don’t have room to store the procedure trays? We’ll store them and ship them to you when you need them!

Examples of current procedure trays:
  • Neonatal and Pediatric
  • PICC insertion trays
  • PICC maintenance trays
  • Breast biopsy trays
  • Circumcision trays
  • Suture Removal Trays
  • “Your Procedure Name Here” Tray
back to top



Endotracheal Tube Holder

ORDER FORM

Marshall Medical Systems:
1 Riverside Road suite #2A
Riverside, IL 60546





Call: 800-649-4028
or click here to contact us.


Product Quick Links:


  • Company Profile


  • Neonatal Equipment


  • Labor & Delivery Equipment


  • OB/GYN Equipment


  • Trauma Equipment


  • Critical Care Equipment


  • Radiology Equipment


  • Respiratory Care Products


  • Surgical Supplies


  • Contact Sales

Home - CompanyProfile - Product Spotlight - BreastHealth - Urology - Neonatal - Labor & Delivery - OB/GYN - Trauma - CriticalCare - Radiology - Respiratory Care - Surgery - Contact Sales
Web Design brought to you by Web Works